<td id="rsnap"><dfn id="rsnap"></dfn></td>

  1. <dfn id="rsnap"></dfn>
    国产在线国偷精品免费看,亚洲一级特黄大片在线观看,色熟妇人妻久久中文字幕,日韩人妻久久精品一区二区,日韩一区二区三区在线观院,九九热精品视频免费在线,国产精品国三级国产专区,91九色国产成人久久精品

    180 LOOP-LOK? TRUSS REINFORCEMENT

    180 Loop-Lok? Truss Reinforcement-4
    180 dub'l loop-lok truss masonry joint reinforcement
    180 Loop-Lok? Truss Reinforcement-1
    180 Loop-Lok? Truss Reinforcement-2
    180 Loop-Lok? Truss Reinforcement-3
    180 Loop-Lok? Truss Reinforcement-4
    180 dub'l loop-lok truss masonry joint reinforcement
    180 dub'l loop-lok truss masonry joint reinforcement
    180 Loop-Lok? Truss Reinforcement-1
    180 Loop-Lok? Truss Reinforcement-2
    180 Loop-Lok? Truss Reinforcement-3
    180 Loop-Lok? Truss Reinforcement-4
    DOCUMENTS & DOWNLOADS
    Submittal SheetsSubmittal SheetsClick on the text link below to download

    Submittal SheetsPDF Downloads

    SafetydataSafetydataClick on the text link below to download

    Safety Data SheetsPDF Downloads

    Submittal SheetsSubmittal SheetsClick on the text link below to download

    LEED / TransparencyPDF Downloads

    CadCadClick on the text link below to download

    CADZIP Downloads

    GearGear
    Submittal Package Generator
    MegaphoneMegaphone
    Ask us a question about this product

    Want to share a product?

    Copy product URL

    Or Share on Social

    PRODUCT DESCRIPTION

    180 Dub'l Loop-Lok? Truss allows in-plane vertical and horizontal movement of masonry wythes while restraining tension and compression.

    • Loops welded shut to maintain allowable tolerance and system integrity.
    • Unlike horizontal eyelets, vertical loops will not clog with mortar as construction progresses.
    • Loops extend one direction only to allow simple placement of insulation.
    • 100% protection against separation of Wire Tie from reinforcement.
    • Also available with the Seismiclip? Interlock System (#180 S.I.S.), suitable for seismic zones.
    • Fabricated in conformance with ASCE/ACI 530 building code requirements for masonry structures and ASTM A 951 (standard specification for masonry joint reinforcement).

    GAUGES:

    • Reinforcing for interior wythe can be STANDARD WEIGHT (9 ga side rods x 9 ga cross rods), EXTRA HEAVY (3/16" side rods x 9 ga Cross Rods), or SUPER HEAVY DUTY (3/16" side rods x 3/16" cross rods)
    • Loops and Ties are 3/16" dia. standard.

    AVAILABLE FINISHES:

    • Mill Galvanized
    • Hot Dip Galvanized
    • Stainless Steel

    NOTE:

    CMU Wall Type

    Veneer Cavity Wall Multi-Wythe

    Finishes/Materials

    Hot-Dip GalvanizedType 304 - Stainless SteelType 316 - Stainless Steel (Special Order)

    Wire Size

    (S) Standard Weight: 9 Gauge Side Rods x 9 Gauge Cross Rods(EH) Extra Heavy: 3/16"? Side Rods x 9 Gauge Cross Rods(SHD) Super Heavy Duty: 3/16"? Side Rods x 3/16"? Cross Rods

    Block Size

    4"6"8"10"12"14"16"

    Backup Type

    CMU

    Eye-Wire/Loop Length

    0.75"1.75"2.25"2.75"3.25"3.75"4.25"

    CMU Wall Type

    Veneer Cavity Wall Multi-Wythe

    Backup Type

    CMU
    This site uses cookies to improve your experience. By clicking, you agree to our Privacy Policy.